#SOUND SIPHON KEEPS RUNNING HOW TO#
How to Replace a Pressure Washer Unloader Valve If you see pressure washer unloader valve symptoms that indicate a failure such as excessive spray and pressure and relief valve tripping, replace the unloader valve. If the unloader valve sticks shut, outlet water pressure builds up until you trigger the spray wand or the pressure relied on valve trips to release excess pressure. The unloader valve recirculates water to the pump inlet when the pump is running but the spray and is not in use. When pressure builds up in the pump because the unloader valve is not opening as it should, the engine cannot continue to turn the pump shaft so the engine dies.Ī failed unloader valve can also cause high pressure at the nozzle. The engine stalls when you are not using the wand.This sysmptoms occurs when the unloader valve sticks open. Nozzle water pressure decreases quickly after you press the wand trigger.This happens when the unloader valve clogs or sticks shut. The thermal release valve opens and sprays steam water from the pump.Each time a gun in the system closes the unloader valve needs to bypass the excess of water, so every gun in the system increases the number of unloader cycles and the possibility of failure.Ĭommon symptoms that indicate you need to replace the pressure washer unloader valve include: Another thing that is commonly associated with an unloader valve failure is multiple gun applications. Small solids like sand grains are very abrasive and damage the metal seal in unloader valves, allowing more water to be bypassed, resulting in less flow through the nozzle. Many unloader valves issues are associated with the quality of the water being used. Like any other mechanical part, unloaders ultimately wear out. Using an unloader beyond its recommended settings and up to the maximum ratings will yield a shorter service. The unloader is used as a safety device to prevent the development of dangerously high pressure and guard against the failure of component parts. Without an unloader valve, dangerously high pressure will be produced when the spray gun is closed because the water being forced out of the pump has no place to go. A positive displacement pump is always delivering a specific volume of water whether the spray gun is open or closed therefore a device is needed to control the direction of flow, either to the open spray gun or redirecting the flow back to the inlet side of the pump when the spray gun is closed.Ĭheck this too: Honeywell Dehumidifier How to & Troubleshooting Guide After the pump is filled with water, the direction of water flow must be controlled with the unloader or regulating valve. Pressure washers are built with one of two types of unloaders: The Trapped Pressure Unloader or the Flow Actuated Unloader. What Does the Unloader Do on a Pressure Washer?

Thaw out the machine completely, including the hose, spray gun and wand.Machine has been stored in freezing temperatures.Check and clean or replace if necessary.Check the water supply and possibility of air seepage.Set the engine speed at proper specifications.Fouled or dirty inlet or discharge valve in pump.
#SOUND SIPHON KEEPS RUNNING INSTALL#


Identifying the root cause is the first step to fixing the problem. Low operating pressure may be due to several reasons. Check that the water supply is turned on and that there is no air in the supply hose. Check the water filter and clean if needed. If the motor starts but there is no build-up of pressure, this may be due to the following reasons: Why is My Pressure Washer Not Building Pressure? Crank open fitting on the high pressure outlet of the pump until water flows out.Clean obstruction or scale deposits from the coil using coil cleaner.Coil on hot water machines is obstructed.Close soap valve or submerge detergent pickup tube into solution.Inlet chemical injection valve is open, without the end of the pickup tube inserted into the detergent.